Tuesday, August 5, 2008

Annealing both ends of copper tubing for refrigeration


A four-turn helical coil is used for this annealing process. The copper tube is placed in the coil and power is applied for a total of 7.5 seconds. At 3.75 seconds the copper tube is rotated half a turn to ensure uniform annealing...

0 comments: